LD-64
Technical Info |
|
| Power |
| |
AC |
115V AC |
DC |
36-55V DC |
HV |
| Rated voltage: |
230 VAC
|
115 VAC
|
24 VDC
|
48 VDC
|
110-240 VDC
95 – 240 VAC
|
| Operating voltage: |
207-264 VAC
|
103-132 VAC
|
12-36 VDC
|
36-55 VDC
|
99-264 VDC
85.5 – 264 VAC
|
| Rated current: |
20 mA @ 230 VAC
|
40 mA @ 115 VAC
|
250 mA @ 12 VDC
|
85 mA @ 36 VDC
|
40 mA @ 95 VAC
|
| Rated frequency: |
48 – 62 Hz
|
48 – 62 Hz
|
DC
|
DC
|
- / 48 – 62 Hz
|
| Connection: |
Screw terminal
|
Screw terminal
|
Screw terminal
|
Screw terminal
|
Screw terminal
|
| Connector size: |
0.2 – 2.5 mm2 24 – 12 AWG
|
0.2 – 2.5 mm2 24 – 12 AWG
|
0.2 – 2.5 mm2 24 – 12 AWG
|
0.2 – 2.5 mm2 24 – 12 AWG
|
0.2 – 2.5 mm2 24 – 12 AWG
|
| RS-422/485 |
|
Electrical specification:
|
RS-422/485 V.11 |
| Data rate: |
2400 bit/s - 375 kbit/s (LD-64) / 500 kbit/s - 1,5 Mbit/s (LD-64F) |
| Connection: |
Screw terminal |
| Connector size: |
0.2 – 2.5 mm2, 24 – 12 AWG |
| Circuit type: |
TNV-1 |
| RS-232 |
|
Electrical specification:
|
RS-232 V.24 |
| Data rate: |
2400 bit/s – 115.2 kbit/s (LD-64) |
| Connector size: |
0.2 – 2.5 mm2, 24 – 12 AWG |
| Circuit type: |
SELV |
| Fiber |
|
Fiber optic specification:
|
Multi mode 820 / 1300 nm Single mode 1300 nm |
| Connection: |
4 ST |
| Alarms |
| Electrical specification: |
Open collector
Max 30V / 80mA
|
| Connection: |
Screw terminal
|
| Connector size: |
0.2 – 2.5 mm2, 24 – 12 AWG
|
| Circuit type: |
SELV
|
| Isolation between interfaces |
| Power to all other |
3000 V RMS @50 Hz and 60 s duration. (LD-64 AC) |
| Power to all other |
3000 V RMS @50 Hz and 60 s duration. (LD-64 115 V AC) |
| Power to all other |
1500 V RMS @50 Hz and 60 s duration. (LD-64 DC) |
| Power to all other |
1500 V RMS @50 Hz and 60 s duration. (LD-64 36-55 V DC) |
| Power to all other |
3750 V RMS @50 Hz and 60 s duration. (LD-64 HV) |
| Standards |
| See Declaration of Conformity, DoC |
| Environmental |
| Temperature, operating: |
5 to 50°C |
| Mechanical |
| Dimension (W x H x D): |
55x100x128 mm |
| Weight: |
0.6 (AC) / 0.3 (DC) kg |
| Mounting: |
DIN-rail |
| Degree of protection: |
IP 20 |
|
|
|