Technical Info » |
|
| Power |
| |
LD-01/BP AC |
LD-01/BP 115 VAC |
LD-01/BP DC |
LD-01/BP 36-55 VDC |
|
| Rated voltage: |
230 VAC
|
115 VAC
|
24 VDC
|
48 VDC
|
|
| Operating voltage: |
207-264 VAC
|
103-132 VAC
|
12-36 VDC
|
36-55 VDC
|
|
| Rated current: |
20 mA @ 230 VAC
|
40 mA @ 115 VAC
|
80 mA @ 24 VDC
|
55 mA @ 36 VDC
|
|
| Rated frequency: |
48 – 62 Hz
|
48 – 62 Hz
|
DC
|
DC
|
|
| Connection: |
Power inlet
|
Power inlet
|
Screw terminal
|
Screw terminal
|
|
| Connector size: |
-
|
-
|
0.2 – 2.5 mm2 24 – 12 AWG
|
0.2 – 2.5 mm2 24 – 12 AWG
|
|
| W1 |
|
Electrical specification:
|
Westermo 10 mA balanced current loop |
| Data rate: |
– 38400 bit/s |
| Connection: |
Screw terminal |
| RS-232 |
|
Electrical specification:
|
RS-232 V.24 |
| Data rate: |
– 38400 bit/s |
| Connection: |
DCE |
| Circuit type: |
SELV |
| Isolation between interfaces |
| Power to all other |
3000 V RMS @50 Hz and 60 s duration. (LD-01/BP AC) |
| Power to all other |
3000 V RMS @50 Hz and 60 s duration. (LD-01/BP 115 VAC) |
| Power to all other |
3000 V RMS @50 Hz and 60 s duration. (LD-01/BP DC) |
| Power to all other |
3000 V RMS @50 Hz and 60 s duration. (LD-01/BP 36-55 VDC) |
| Line to all other |
1500 V RMS @50 Hz and 60 s duration. (LD-01/BP AC) |
| Line |
1500 V RMS @50 Hz and 60 s duration.(LD-01/BP 115 VAC) |
| Line |
1500 V RMS @50 Hz and 60 s duration. (LD-01/BP DC) |
| Line |
1500 V RMS @50 Hz and 60 s duration. (LD-01/BP 36-55 VDC) |
| Standards |
| See Declaration of Conformity, DoC |
| Environmental |
| Temperature, operating: |
5 to 50°C |
| Mechanical |
| Dimension (W x H x D): |
55x100x128 mm |
| Weight: |
0.5 kg |
| Mounting: |
DIN-rail |
| Degree of protection: |
IP 20 |
|
|
|